Skip to main content
Skip to main content

Model your project savings and peak-demand reduction

Calculate ROI
Off-Grid SolutionsTelco Towers
For MCMC NFP Licensees & Tower Co-Location Providers

Solar Power for
Telco Towers, Designed with Reference to KPKT Guidelines

From ASSR to a site-specific design — for every Malaysian site, from Klang Valley densification rooftops to weak-grid sites in Sabah and Sarawak (via local partners). Hybrid solar + battery for 30m H, SST and monopole towers, feeding off 1-phase rural pole or 3-phase commercial supply.

104m+
Power runs supported
1-phase / 3-phase
Grid input compatible
30m+
Tower height (H/SST/Monopole)
KPKT
Guidelines referenced in design

Pricing per tower is set by your site survey. Volume pricing for multi-site programmes.

SEDA Documentation Support
TNB Application Support
References On Request
ASSR Integration

Send Us Your ASSR.
We Add the Solar Layer.

Your acquisition team already produces an Acquisition Site Survey Report for every candidate site. We add the solar + battery layer on top — no new survey work, no parallel process, no slowdown.

1

Send ASSR

Upload your standard ASSR (any candidate option, C1–C4). PDF, drive link, or WhatsApp — whatever your acquisition team uses.

2

We Design

Solar + battery sizing, structural drawings referencing KPKT guidelines, single-line electrical, BOM with delivered cost to site.

3

You Approve & We Install

PO issued, materials staged, install to the schedule agreed in your proposal. Commissioning in your maintenance window.

What we extract from your ASSR

  • Site coordinates (lat/long) and elevation
  • Tower height, structure type, candidate option (C1–C4)
  • Distance to commercial power and phase availability
  • KPKT compliance status and city council jurisdiction
  • Survey date, access road condition, security risk notes
Quoted per Site

Telco Tower Solutions

Every tower is sized from its ASSR or site survey. Multi-site programmes are quoted per project.

Quoted per site — sized from your ASSR or site survey

Telco tower systems are not catalogue products. We size the solar, battery and inverter from your ASSR, load profile and site survey, and quote per tower or per programme.

  • Quoted per site; no fixed package prices
  • Backup duration depends on battery size and your load, and is confirmed in the design
  • Switchover time depends on the equipment and is confirmed in the design

* Pricing is quoted per site; multi-site programmes are quoted per project. Outright purchase or a C&I hire purchase (Mitsubishi HC Capital) financing options are available for portfolio-scale rollouts.

A remote telecommunications tower site with a fenced solar array and battery enclosure in the jungle
Sabah and Sarawak sites via local partners

Where We
Deploy

Telco towers needing solar exist across every Malaysian state — not just remote islands. We design for four distinct site profiles, each with its own power problem and economic case.

Urban Densification Towers

Klang Valley, Penang, JB

Small-cell and macro-cell rooftop deployments where landlord power is unreliable or metered separately. Hybrid solar + battery cuts site OPEX and avoids generator-noise complaints.

Rooftop small-cell · landlord-power independence

Highway & Industrial Corridor Towers

PLUS, ELITE, KESAS, NSE

Long-haul towers near highways, often with weak grid feeds. Solar + battery supports fail-safe coverage during state-wide outages and protects toll-system backhaul.

Highway coverage · outage-resilient backhaul

Rural Peninsular

East Pahang, Kelantan, Terengganu, FELDA

Long power runs, monsoon outages, diesel-supplied today. Hybrid solar replaces the diesel OPEX and the weekly fuel-truck visit while reducing reliance on diesel through the wet season.

Diesel displacement · monsoon resilience

East Malaysia & Remote Sites

Sabah, Sarawak, Labuan

Illustrative scenario — not a Trexon project: a 30m H tower on an island, designed for monsoon resilience, anti-theft anchoring, and 1-phase pole-supply integration where commercial power is 500m+ from the tower base.

Island & interior · remote build designed to KPKT guidelines

Monsoon Resilience

Battery autonomy is sized per site, with longer autonomy for critical macro sites.

Anti-Theft Hardened

Locked enclosures, GSM tamper alerts, anti-pry mounts — designed for unmanned remote sites.

RAN-Safe Install

RF-zone aware crews, evening commissioning, NOC coordination throughout cutover.

Telco Infrastructure FAQ

Questions from NFP power-design teams and site acquisition managers.

Can you work directly from our existing ASSR documents?

Yes. Send us the standard Acquisition Site Survey Report (ASSR) you already produce for tower acquisition. We extract site coordinates, tower height and structure type, distance to commercial power, KPKT compliance status, and the chosen candidate option (C1–C4). You don't need to produce any new survey artefacts for the solar layer — we work from what your acquisition team has already signed off.

How do you handle KPKT compliance for the solar additions?

Structures are designed with reference to the KPKT 2018 telecommunications infrastructure guidelines. We prepare structural drawings for endorsement by a third-party Professional Engineer where required, wind-load calculations for the relevant Sabah/Sarawak zones, and earthing schematics for your tower approval pack; acceptance rests with the site owner and the local authority (e.g. DBKK, MBKS).

1-phase vs 3-phase grid input — which do you support?

Both. Rural Sabah and Sarawak sites are commonly fed by 1-phase pole supply 100m+ away from the tower base, and our hybrid inverters are sized accordingly. For 3-phase commercial power (typical at peri-urban macro sites) we deploy 3-phase string inverters with grid-export disable and load-side connection, configured to the applicable TNB/SESB connection rules.

Can you evaluate solar feasibility across our C1–C4 candidates simultaneously?

Yes. Send us the candidate options pack and we'll return a comparative solar+battery sizing for each — factoring shading, road access for material delivery, security risk profile, and cost of running power to the tower. This usually shifts which candidate the acquisition team picks, because the cheapest land lease isn't always the cheapest power solution.

Hybrid grid+solar vs pure off-grid — when do you recommend each?

Hybrid is the default for any site where commercial power is within ~500m and the 1-phase or 3-phase supply has acceptable availability. Solar+battery covers outages and reduces diesel runtime; the grid handles long monsoon stretches. Pure off-grid is reserved for sites where the grid is >500m away, the trenching cost exceeds the lifetime fuel saving, or terrain (island, river crossing, protected forest) makes a power run impractical.

Multi-site rollout timeline?

The schedule is set in your proposal according to programme scale (it covers ASSR review, design, KPKT submission, material staging, install and commissioning). Repeat deployments in the same region are faster because design templates and material kits are reused.

Anti-theft for remote panels and batteries?

Standard on every remote site. Locked steel enclosures for inverters and batteries, gravel-base anti-pry mounts on ground-mount arrays, panel-edge security bolts, and GSM tamper alerts that ping the NOC the moment an enclosure is opened. Optional: solar-powered IP CCTV with motion detection and night vision integrated into the existing tower CCTV feed.

Can you commission within our network maintenance window?

Yes. Evening and overnight commissioning is standard for live macro sites — we coordinate the cutover with your NOC, run on temporary feed during the switch, and limit RF-zone work to scheduled windows. For greenfield sites with no live traffic, we commission in daylight.

Commercial Solar

Custom Solar Design for Your Tower Site

Send your ASSR or candidate pack and we'll reply with the next steps.

  • Custom system design for your site
  • Sizing based on your electricity usage and load
  • SEDA-registered PV Service Provider (RPVSP-2026/373) · SSM 201301044881 (1074704-D)

Prefer to talk first? Message our commercial team on WhatsApp.

WhatsApp Us

Request a Quote

Fill in your details and our commercial team will review your request during business hours

Attach one Acquisition Site Survey Report. It is stored privately against this exact tower request for the engineering review.

Your details are used only to assess and respond to this project request.

Ready to Solar-Enable
Your Next Tower?

Whether you're evaluating a single urban densification rooftop or rolling out 50 sites across rural and remote Malaysia, send us the ASSR and we'll come back with sizing, drawings for your approval pack, and delivered-to-site pricing.