Bought a second-hand house with solar? Buying a building with rooftop PV? Suspect your installer cut corners? We perform independent solar PV inspection — drone thermal imaging, I-V curve trace, structural check, electrical safety audit. RM800–RM3,500 flat fee.
From RM 800 residential · RM 3,500 industrial / forensic
Used by buyers, banks, insurance loss adjusters, and warranty claimants.
Four scenarios where an independent inspection protects your money and your rights.
Buying a house or building that already has solar installed? Don't inherit someone else's problems. We inspect the system before you sign — identifying panel degradation, wiring faults, and warranty transfer validity before the deal closes.
Your installer says the job is done. We verify independently: panel tilt, string wiring, inverter commissioning data, earthing, and DC/AC ratings all match the signed contract. Nothing is signed off until we say it checks out.
Manufacturer claiming the degradation is within spec? Installer saying the fault was a lightning act of God? We produce an independent stamped engineering report with I-V curve data and thermal evidence to support your claim.
After lightning, storm, flood, or fire damage, your insurer will require an independent loss adjustor report. We provide a forensic-grade inspection with drone thermal imagery and electrical readings accepted by Malaysian insurers.
A full-system audit — from panel cells to earthing rods.
Drone-mounted IR camera identifies hot cells, bypass diode failures, soiling, shading, and delamination that are invisible to the naked eye — at panel-level resolution across the full array.
String-by-string I-V curve measurements verify actual power output against nameplate ratings. Deviations identify degraded panels, failed bypass diodes, or mismatch losses before they compound.
We pull inverter event logs, check MPPT efficiency, verify grid frequency ride-through settings, and compare daily yield to modelled performance — flagging communication faults, temperature de-rating, and firmware issues.
MC4 connector torque, cable sizing adequacy, string fuse ratings, AC isolator labelling, PVC conduit integrity, and combiner box terminations — all checked against Malaysia's MS IEC 62548 and TNB grid-tie standards.
Ballast weight, clamp torque, rail spacing, and waterproofing at every roof penetration. We document corrosion, inadequate sealing, and non-compliant structural fixing patterns with photos.
Array earthing continuity, equipotential bonding, lightning protection system (if present) adequacy check, and surge protection device (SPD) ratings — critical for insurance validity.
Flat fee — no hidden travel charges within Peninsular Malaysia.
≤10 kWp · single house
RM 800
10–100 kWp
RM 1,800
100 kWp+ · litigation / insurance grade
RM 3,500
From booking to stamped report in under a week.
Submit your request via WhatsApp or the contact form. We confirm the site visit date within 24 hours and share a pre-inspection checklist.
Our inspector attends with drone, I-V tracer, and thermal camera. Residential visits take half a day; commercial and industrial take a full day.
Thermal imagery is analysed and I-V curves are compared against nameplate data and modelled performance. Takes 3 business days.
You receive a PDF report with findings, photos, and a remedial action list. Industrial / Forensic tier includes PE stamp suitable for warranty, insurance, and legal proceedings.
Don't sign off on a solar system without knowing what you're accepting. Our inspectors carry their own equipment — no dependency on the installer.